Veterinary Modular Monitor HD11-VET

HD11-VET

Monitoring range: HR, ECG, SPO2, NIBP, RESP, TEMP, CO2

Data storage of more than 1200 hours

Mainstream/bypass ETCO2 interface as standard

 


Product Detail

Parameters

1280*800 LCD display
Mainstream/bypass ETCO2 interface as standard
More than 5 languages operation interface (optional)
20 kinds of arrhythmia event alarm, support ST segment analysis function
Trigger printing function, each abnormality is recorded in time
Large capacity built-in lithium battery, continuous working time ≥ 300 minutes
Anti-defibrillation, electric knife, grid, inotropic interference

Accessories:

Five-lead heart wire*1
Body surface temperature probe*1
Blood oxygen probe*1
Blood pressure extension tube*1
Blood pressure cuff*4 (disposable)
Disposable electrode sheets*25 or clips*25

ECG:
Lead selection: three-/five-lead standard; up to 7 leads can be displayed on the same screen
Ⅰ, Ⅱ, Ⅲ, AVR, AVL, AVF, V chest leads
ECG value detection range: 15~350bpm
Resolution: 1bpm
Measurement accuracy: ±2% or ±2bpm of the greater
Frequency response: 0.67 Hz-40 Hz
S-T segment monitoring: -2.0mV~2.0mV
Electrode off indication: sound, light prompt
Scan speed: 6.25, 12.5, 25, 50mm/sec
Gain selection: ×0.125, ×0.25, ×0.5, ×1, ×2, ×4, automatic
ECG calibration: 1mV+5%
Protection isolation withstand 4000V/AC/50Hz voltage;
ECG cable lead wire: 3/5 lead
Standard configuration: five-lead buckle type universal ECG cable
Select configuration: research-specific ECG cable cable, (custom small clip)
Alarm: alarm value upper and lower limits can be set, automatic memory; with alarm review

 

Oxygen saturation:
Display: Oximetry value, pulse bar graph, waveform, pulse value
Oximetry range: 0%-100% equine/canine/feline
Resolution: 1%
Accuracy: ±3% (not defined below 70%)
Pulse rate.
Measurement range: 30 to 280bpm
Pulse rate accuracy: ±2bpm
Alarm range: 20 ~ 300bpm, the lower limit can not be greater than the upper limit
Standard configuration: canine clip type, feline clip type
Select configuration: bundle type
Alarm value: upper and lower limits can be set, automatic memory

 

Non-invasive blood pressure:
Measurement method: oscillometric method
Measurement parameters: systolic blood pressure, diastolic blood pressure, mean pressure
Working mode: manual, automatic, continuous measurement
Units: mmHg/kPa optional
Automatic measurement mode measurement interval time: 2.5 ~ 120min ten levels adjustable
Overpressure protection: software and hardware overpressure protection

Cuff pressure range: 0-300 mmHg
Standard configuration: 4-8, 6-11, 7-13, 8-15 cm
Select configuration: None
Alarm setting range.
Systolic pressure: 40~255 mmHg, and the lower limit cannot be greater than the upper limit (Marko), the
40~200mmHg, and the lower limit cannot be greater than the upper limit (Canidae), and
40~135mmHg, and the lower limit cannot be greater than the upper limit (feline).
Diastolic blood pressure: 10~195mmHg, and the lower limit cannot be greater than the upper limit (Equidae), and
10~150mmHg, and the lower limit cannot be greater than the upper limit (Canidae), and
10~110mmHg and the lower limit cannot be greater than the upper limit (feline).
Mean pressure: 20~215mmHg, and the lower limit cannot be greater than the upper limit (Equidae), and
20~165mmHg, and the lower limit cannot be greater than the upper limit (Canidae), and
20~125mmHg, and the lower limit cannot be greater than the upper limit (feline).
Alarm display error: no greater than ±5% of the set value.

 

Body temperature:
Body temperature measurement range: 15℃~50℃
Body temperature measurement error: no greater than ±0.1℃
Resolution: 0.1℃
Accuracy: ± 0.2 ℃ (including the error of the sensor)
Standard configuration: body surface permanent body temperature probe
Select configuration: esophageal body temperature probe, rectal body temperature probe
Alarm value: upper and lower limits can be set, automatic memory
Alarm: alarm settings can be set for all monitoring parameters, and has an alarm device that emits sound and light, and can cancel the alarm

 

Respiration:
Measurement method: thoracic impedance method
Respiratory rate measurement range and accuracy
Measurement range: Equidae: 0~ 120rpm.
Canine/Feline: 0~ 150rpm.
Measurement accuracy: 10~150 rpm ±2 rpm or ±2%, whichever is greater.0~9 rpm is not defined.
Respiration rate measurement resolution
Resolution: 1 rpm
Asphyxia alarm delay time
Can be set as: 20s, 25s, 30s, 35s, 40s, 45s, 50s, 55s, 60s
Respiration rate alarm limit range
Alarm limit can be set from 2 to 150rpm