1280*800 LCD isibonisi
 I-Mainstream/bypass interface ye-ETCO2 njengejwayelekile
 Ngaphezulu kwezilimi ezi-5 zokusebenzelana (kuyakhetheka)
 Izinhlobo ezingama-20 ze-alamu yomcimbi we-arrhythmia, isekela umsebenzi wokuhlaziya ingxenye ye-ST
 Qalisa umsebenzi wokuphrinta, ukungajwayelekile ngakunye kuqoshwa ngesikhathi
 Umthamo omkhulu webhethri ye-lithium eyakhelwe ngaphakathi, isikhathi sokusebenza esiqhubekayo ≥ imizuzu engama-300
 I-Anti-defibrillation, ummese kagesi, igridi, ukuphazamiseka kwe-inotropic
Izinsiza:
Intambo yenhliziyo yomthofu emihlanu*1
 I-probe yezinga lokushisa lomzimba*1
 I-blood oxygen probe*1
 Ishubhu yokwandisa umfutho wegazi*1
 Ikhafu yomfutho wegazi*4 (iyalahlwa)
 Amashidi e-electrode alahlwayo*25 noma iziqeshana*25
I-ECG:
 Ukukhetha okuholayo: izinga lokuhola okuthathu/okuhlanu;kufika ku-7 imikhondo ingaboniswa esikrinini esifanayo
 Ⅰ, Ⅱ, Ⅲ, AVR, AVL, AVF, V imikhondo yesifuba
 Ibanga lokutholwa kwenani le-ECG: 15~350bpm
 Ukulungiswa: 1bpm
 Ukunemba kokulinganisa: ±2% noma ±2bpm kokukhulu
 Impendulo yemvamisa: 0.67 Hz-40 Hz
 Ukuqapha kwengxenye ye-ST: -2.0mV~2.0mV
 I-Electrode off inkomba: umsindo, ukukhanya
 Isivinini sokuskena: 6.25, 12.5, 25, 50mm/sec
 Ukukhethwa kokuthola: ×0.125, ×0.25, ×0.5, ×1, ×2, ×4, okuzenzakalelayo
 Ukulinganiswa kwe-ECG: 1mV+5%
 Ukuhlukaniswa kokuvikela ukumelana ne-voltage engu-4000V/AC/50Hz;
 Intambo eholayo yekhebula ye-ECG: 3/5 lead
 Ukucushwa okujwayelekile: uhlobo lwekhebuli ye-ECG enentambo yokuhola emihlanu
 Khetha ukumisa: ikhebula lekhebula le-ECG eliqondene nocwaningo, (isiqeshana esincane sangokwezifiso)
 I-alamu: inani le-alamu lingasethwa, inkumbulo ezenzakalelayo;ngokubuyekezwa kwe-alamu
Ukugcwala komoyampilo:
 Bonisa: Inani le-Oximetry, igrafu yebha yokushaya, i-waveform, inani lokushaya kwenhliziyo
 Ibanga le-Oximetry: 0% -100% i-equine/canine/feline
 Isixazululo: 1%
 Ukunemba: ±3% (akuchazwanga ngaphansi kuka-70%)
 Izinga lokushaya kwenhliziyo.
 Ibanga lokulinganisa: 30 kuya ku-280bpm
 Ukunemba kwesilinganiso sokushaya kwenhliziyo: ±2bpm
 Ibanga le-alamu: 20 ~ 300bpm, umkhawulo ophansi awukwazi ukuba mkhulu kunomkhawulo ophezulu
 Ukucushwa okujwayelekile: uhlobo lwesiqeshana se-canine, uhlobo lwesiqeshana se-feline
 Khetha ukumisa: uhlobo lwenqwaba
 Inani le-alamu: imikhawulo ephezulu naphansi ingasethwa, inkumbulo ezenzakalelayo
I-non-invasive blood pressure:
 Indlela yokulinganisa: indlela ye-oscillometric
 Izilinganiso zokulinganisa: umfutho wegazi we-systolic, umfutho wegazi we-diastolic, umfutho wegazi
 Imodi yokusebenza: ukulinganisa okwenziwa ngesandla, okuzenzakalelayo, okuqhubekayo
 Amayunithi: mmHg/kPa ngokuzithandela
 Isikhathi sokulinganisa semodi yokulinganisa ezenzakalelayo: 2.5 ~ 120min amazinga ayishumi alungisekayo
 Ukuvikelwa kokucindezela ngokweqile: isoftware kanye nokuvikelwa kokucindezela kwehadiwe ngokweqile
Ibanga lokucindezela kwe-Cuff: 0-300 mmHg
 Ukucushwa okujwayelekile: 4-8, 6-11, 7-13, 8-15 cm
 Khetha ukumisa: Akukho
 Ibanga lokusetha i-alamu.
 Ingcindezi ye-Systolic: 40~255 mmHg, futhi umkhawulo ophansi awukwazi ukuba mkhulu kunomkhawulo ophezulu (Marko),
 40 ~ 200mmHg, futhi umkhawulo ophansi awukwazi ukuba mkhulu kunomkhawulo ophezulu (Canidae), futhi
 40~135mmHg, futhi umkhawulo ophansi awukwazi ukuba mkhulu kunomkhawulo ongaphezulu (inkabi).
 Umfutho wegazi we-Diastolic: 10 ~ 195mmHg, futhi umkhawulo ophansi awukwazi ukuba mkhulu kunomkhawulo ophezulu (Equidae), futhi
 10~150mmHg, futhi umkhawulo ophansi awukwazi ukuba mkhulu kunomkhawulo ongaphezulu (Canidae), futhi
 10~110mmHg futhi umkhawulo ophansi awukwazi ukuba mkhulu kunomkhawulo ongaphezulu (inkabi).
 Ingcindezi emaphakathi: 20~215mmHg, futhi umkhawulo ophansi awukwazi ukuba mkhulu kunomkhawulo ophezulu (Equidae), futhi
 20~165mmHg, futhi umkhawulo ophansi awukwazi ukuba mkhulu kunomkhawulo ongaphezulu (Canidae), futhi
 20~125mmHg, futhi umkhawulo ophansi awukwazi ukuba mkhulu kunomkhawulo ongaphezulu (inkabi).
 Iphutha lokubonisa i-alamu: alikho ngaphezu kuka-±5% yenani elimisiwe.
Izinga lokushisa lomzimba:
 Ibanga lokulinganisa izinga lokushisa lomzimba: 15℃~50℃
 Iphutha lokulinganisa izinga lokushisa lomzimba: alikho ngaphezu kuka-±0.1℃
 Ukulungiswa: 0.1℃
 Ukunemba: ± 0.2 ℃ (kuhlanganise nephutha lenzwa)
 Ukucushwa okujwayelekile: indawo yomzimba ehlala unomphela izinga lokushisa lomzimba
 Khetha ukumisa: i-probe yezinga lokushisa lomzimba lomphimbo, i-rectal lokushisa lomzimba
 Inani le-alamu: imikhawulo ephezulu naphansi ingasethwa, inkumbulo ezenzakalelayo
 I-alamu: izilungiselelo ze-alamu zingasethwa kuwo wonke amapharamitha okuqapha, futhi inedivayisi ye-alamu ekhipha umsindo nokukhanya, futhi ingakhansela i-alamu.
Ukuphefumula:
 Indlela yokulinganisa: indlela ye-thoracic impedance
 Ibanga lokulinganisa izinga lokuphefumula nokunemba
 Ibanga lokulinganisa: Equidae: 0 ~ 120rpm.
 I-Canine / Feline: 0 ~ 150rpm.
 Ukunemba kokulinganisa: 10~150 rpm ±2 rpm noma ±2%, noma yikuphi okukhulu.0~9 rpm akuchazwanga.
 Ukulungiswa kokulinganisa izinga lokuphefumula
 Ukulungiswa: 1 rpm
 Isikhathi sokulibaziseka kwe-alamu ye-Asphyxia
 Ingasethwa ngokuthi: 20s, 25s, 30s, 35s, 40s, 45s, 50s, 55s, 60s
 Ibanga lomkhawulo we-alamu yezinga lokuphefumula
 Umkhawulo we-alamu ungasethwa kusuka ku-2 kuye ku-150rpm